Schlage co200 manual

Schlage manual

Add: ibubiboj72 - Date: 2020-12-18 07:47:02 - Views: 9341 - Clicks: 2343

All locks have a default programming code of 97531 and “. 1 • Schlage • Schlage utility software user&39;s guide The Schlage Utility Software is an application that runs on the Schlage Handheld Device (HHD). CORE SERIES OFFLINE LOCKS. One beep will sound and one red blink will occur with each press. CO-Series Exit Trim for Schlage CO-100-993; Schlage CO-200-993; Schlage CO-220-993; Schlage CO-250-993. Demo of programming the push button lock.

CO-100 models are designed for use as easy to manage, low maintenance locks that use 3-6 digit PIN codes as credentials. ÎProgramming mode will time out if no entry is made in 20-25 seconds. The physical lock Keypad option is mandatory for local manual lock programming. This will return a lock to factory defaults and settings, removing all previous programming. The Schlage button will light green for one second and a one-second beep will sound, indicating that the lock has been reset.

Time out is indicated by three left and nine right red blinks of the Schlage button. Administrator level users can program it right at the door to add or delete user PIN codes or change preferences or functions at any time. Instructions & Manuals. 25 Grade 1 certified and UL 294 listed. Manual programming instructions Important notes: L Wait for the Schlage button LEDs to stop flashing before continuing to the next step. The Hand Held Device (HHD) or Schlage Utility Software (SUS) will not connect to the CO200? CO-Series Service Manual CO-200/250-CY, ALL MODELS EXCEPT KEYPAD ONLY Exterior CO-200 Shown Here Part Part Number Description Number Number Description Number Escutcheon Latch, Escutcheon CYLatch, CY See pg.

Select Software Alliance members also offer access control solutions for the CO-200 with added capability that can include lock schedules and audits. Either Schlage Express or SMS Select PC software can be used to program the AD200 and CO200 locks using the HHD. This edition lists components of CO-Series locks manufactured after November. The CO-200 is computer or manually programmable with users rights stored on the lock. CS200 Series interconnected locks provide exceptional performance, aesthetics and flexibility for both residential and commercial applications.

CO-200 Offl ine Lock User Guide OVERVIEW The Schlage CO-200 is an off-line electronic lock in the CO-Series product line. It is used to configure, edit and program all supported devices. CO-200 can work in the same offline system as AD-200, CO-220 and CT5000. The CO-200 offers additional creden-tial options that include keypad, proxim-ity cards, magnetic stripe cards and dual. reliability you have come to expect from Schlage. Schlage Rekeying Manual 1. Schlage CO-200 Manuals & User Guides.

4MB FE576 - Keypad Lock with Built-In Alarm and Auto-Lock Installation Instructions 5. View and Download Schlage CO-993 installation instructions manual online. Resolution: Make sure the lock AA batteries are good. This manual contains a complete listing of available parts and assemblies for CO-Series cylindrical, mortise, and exit trim locks manufactured by Schlage Lock Company. User Manuals (Englis. CO-200 Offl ine Lock User Guide MANUAL LOCK PROGRAMMING Left LED Right LED TIPS The Schlage button has two different LEDs, one on the left and one on the right.

Resolution: Once disabled via the SUS application, the CO lock will no longer delay the access for valid credentials. Our co200 passion for door hardware is what drives us to develop the products that keep you, and what matters most to you, secure. CO-200 Offl ine Lock User Guide OVERVIEW The Schlage CO-200 is an off-line electronic lock in the CO-Series product line.

How to Factory Reset a Schlage CO-200 lock. User Manuals, Guides and Specifications for your Schlage CO-100-CY-70-KP-RHO-626 Locks. Schlage CO-100-CY-70-KP-RHO-626 Manuals & User Guides.

Schlage CO Series locks are available in three models, the CO-100, CO-200 and CO-250 locks. Database contains 5 Schlage CO-200 Manuals (available for free online viewing or downloading in PDF): Operation & user’s manual, Installation instructions manual, Instruction manual, Battery replacement manual. † The lock is confi gured to operate as Classroom/Storeroom function. How to program a Normal Use PIN code on a Schlage CO-100, CO-200, and AD-200 series. L Programming mode will time out if no entry is made in 20-25 seconds. • The lock is confi gured to operate as Classroom/Storeroom function. It features single motion egress, retracting both the latch and deadbolt simply by rotating the inside lever, to meet Life and Safety code requirements. Download Operation & user’s manual of Schlage CO-200 Lock, Locks for Free or View it Online on All-Guides.

Tools Don’t use a power drill! If you still have questions about your product, visit our FAQ page for additional answers. They can be manually programmed for basic use or managed with PC-based Schlage Express™ software. • The lock is powered by four (4) AA batteries. The CO-Series is ANSI/BHMA 156. CO-100 locks pdf manual download. :Canada:Mexico:Support.

For 100 years, Schlage has been building a legacy of security and innovation. Optional Offi ce or Privacy functions are available. Supported AD-Series Locks AD-200 AD-201 AD-250 AD-300 AD-301 AD-400 AD-401 Supported CO-Series Locks CO-200 CO-220 CO-250. User Manuals (English. Once a lock has been programmed with an HHD and PC software, local manual lock programming is disabled. 4MB F170 - Non-turning Knob/Lever Door Prep Template. CO-200 Offline Electronic Lock Features • Computer programmable with audit trail • Up to users & up to audits* • Up to 32 holidays & 16 time zones* • ANSI/BHMA Grade 1 certified and UL 294 listed. 50 Screws, Escutcheon Screws, Latch 7 *** Baseplate Subassembly & Reader Module, CY See pg.

Database contains 1 Schlage CO-100-CY-70-KP-RHO-626 Manuals schlage co200 manual (available for free online viewing or downloading in PDF): Installation instructions manual. Description Part no. 6 • Schlage • CO Series service manual Locks CO-100-CY Keypad Only, ExteriorNo.

Schlage CO-200 User Manual. Using a remote fob worn schlage by the teacher, lockdown can occur within 2 seconds of pressing the fob button. (Metal Door) CO-MS Mortise CO-200/250 Template - CO204 Mortise Deadbolt Lock (Wood Door) CO-MD Mortise Deadbolt CO-100/200/250 Template - CO105. Like all electronic access control solutions, CO-100 helps reduce or eliminate the need to issue keys - serving to protect the integrity of the key system. Resolution: When in its “Active state”, the mechanical key switch can prevent USB connection. • The lock is configured to operate as Classroom/Storeroom function. CO-200 Offl ine Lock User Guide Manual Programming Commands ÎCommands are confi rmed by fi schlage co200 manual ve alternating green blinks of the Schlage button.

The Handheld Device (HHD) used in conjunction with your access control software, allows you to easily add or delete users and retrieve audits. • This product is listed for UL294 and ULCS319. Contact Schlage Door Lock’s customer support team via email or phone number here for product support, warranty claims or additional questions. CO-220 Classroom Lockdown Solution CO-220 is a standalone classroom lockdown solution that enables the immediate lockdown of up to ten CO-200s within range should an emergency arise. Schlage CO-200-CY-Proximity Locks with keypad, The CO-Series standalone electronic locks by Schlage provide the security, efficiency and convenience of electronic access control without the cost or complexity of a fully schlage co200 manual networked system. View and Download Schlage CO-100 user manual online. The CO-100 is manually pro-grammed using only the keypad and can store up todigit PIN codes stored in the lock. 1 Phillips screwdriverU.

CO-993 door locks pdf manual download. † The lock is powered by four (4) AA batteries. User Manuals, Guides and Specifications for your Schlage CO-200 Lock, Locks. Press and release the Schlage button three (3) times within 10 seconds of the beeps and blinks at step 4. Resolution: The coin cell Nuisance Delay on CO200 and CO250 can be temporarily disabled using the Schlage Utility Software. Browse our manuals, warranty information and installation videos to ensure the proper fit. Release the Schlage button.

However, key override is a standard feature and CO-100 is offered in all Schlage open or restricted key systems, plus many competitive cylinder types. Optional Office or Privacy functions are available. 7‡ Baseplate Assembly, CY.

Schlage co200 manual

email: napusaf@gmail.com - phone:(435) 326-5989 x 8630

Mesa de elevacion manual - Financial european

-> Logmein help manual
-> Panasonic fl360l manual

Schlage co200 manual - Owners mandoline manual


Sitemap 1

Pdf do manual de instrucoes da maquina galoneira siruba - Nicoclub service nissan forum